Jinma Electric is deeply engaged in the field of power equipment, and has fully investigated the characteristics of the South American power grid and the electricity demand of the heating mixing furnace. Jinma 220V to 105V three-phase isolation transformer is specially designed for the export scene of the heating mixing furnace and has two core functions:
The South American 220V three-phase voltage is accurately converted to 105V, which exactly matches the voltage requirements of the heating module and the mixing motor, ensuring that the furnace temperature is stable in the set range, the mixing speed is uniform and there is no fluctuation, and the production efficiency and product quality deviation caused by voltage mismatch are avoided.
Built-in three-phase isolation windings cut off the clutter signal and grounding interference of the power grid to prevent power grid fluctuations from affecting the temperature control chip and sensor, especially suitable for chemical and food processing scenarios that require precise temperature control, effectively reducing the probability of false positives and downtime.
| Category | Item | Specification |
| Electrical | Rated Capacity | 5kVA-50kVA |
| Phase | Three-phase | |
| Voltage | 220V AC / 105V AC | |
| Efficiency | ≥95% | |
| Structure & Protection | Insulation Class | Class H (180℃) |
| Core & Winding | Silicon steel core, high temp resistant coil | |
| Housing | Anti-corrosion & high temp resistant shell | |
| Protection | Over-current / Overload / Over-temperature | |
| Environment & Installation | Cooling Mode | Customized |
| Max Ambient Temp | 180℃ |
If the heating and mixing furnace adapted to 105V is directly connected to the 220V power grid in South America, it will cause a series of chain problems.:
The transformer works based on the principle of electromagnetic induction: the primary winding is connected to the South American 220V three-phase power grid, and the secondary winding outputs a 105V three-phase voltage to complete the voltage level conversion.;
Electrical isolation is achieved through insulation between the primary and secondary windings, so that the furnace body side circuit and the power grid side circuit are electrically independent of each other, and the power grid clutter and grounding interference cannot be transmitted to the equipment, and the temperature control and sensing system are protected from the source.
For the different specifications of the heating and mixing furnace, Jinma Electric provides personalized supporting services: the power covers the full range of 5kVA-50kVA, and the type can be accurately selected according to the heating power of the furnace body and the parameters of the mixing motor;
If the equipment has special installation dimensions or interface requirements, customized production can also be provided to ensure that the transformer is perfectly adapted to the furnace body.
The professional technical team can provide remote installation guidance and post-maintenance consultation to help South American customers quickly complete equipment commissioning and commissioning, and solve multinational after-sales problems.
Can’t.Conventional isolation transformers only complete the voltage level conversion and electrical isolation, and do not change the frequency.If the frequency of the local power grid in South America is inconsistent with the rated frequency of the equipment, a separate evaluation of the supporting plan is required.
It depends on the difference between the rated voltage of the equipment and the voltage of the local power grid, as well as the demand for electrical isolation on site.It is recommended to provide equipment nameplate parameters and local power grid information for evaluation by the manufacturer.
It is determined comprehensively according to the heating power of the furnace body and the parameters of the stirring motor.Jinma Electric’s power covers 5kVA-50kVA, and can provide selection suggestions.
Support customized production, and the installation size and interface requirements can be adapted according to the furnace body structure.
It is recommended to refer to the voltage, frequency, phase number and other information provided by the local power supply department, and provide it to the manufacturer for selection and scheme design.